Abstract in English:
ABSTRACT.- Maia L., Souza M.V., Alves G.E.S., Júnior J.I.R., Oliveira A.C., Silva Y.F.R.S. & Zandim B.M. 2009. [Platelet-rich plasma in the treatment of induced tendinitis in equines: Ultrasonographic evaluation.] Plasma rico em plaquetas no tratamento de tendinite induzida em eqüinos: avaliação ultra-sonográfica. Pesquisa Veterinária Brasileira 29(3):241-245. Setor de Clínica e Cirurgia de Grandes Animais, Departamento de Veterinária, Universidade Federal de Viçosa, 36570-000 Viçosa, MG, Brazil. E-mail: msouza@ufv.br
The objective of the study was to evaluate the effect of platelet-rich plasma (PRP) in the treatment of induced tendinitis in the superficial digital flexor tendon (SDFT) of horses through ultrasonographic evaluation. Thus, six 8 to15-year-old healthy gelding horses (=12 years) were used. Tendinitis of the SDFT was provoked in both forelimbs via intratendineous administration of 2.5mg of collagenase (2.5mg.mL-1), what was considered as beginning of the experimental phase. Twelve days after induced tendinitis, the horses were submitted to two treatments: (1) in the lesion caused in the right SDFT (treated group, TG), 2.5mL of PRP activated with calcium chloride at 0.0125mol.L-1, at concentrations from 320,000 to 500,000 platelets.µL-1, were administered; (2) in the tendinitis of the left SDFT (control group, CG), 2.5mL of 0.9% saline solution was administered. After 5 days, the animals were submitted to controlled and progressive physical activity during 30 days. Ultrasonographic examinations were carried out before and after tendinitis induction (48 hours after and on experimental days 7, 12, 14, 21 28, 35 and 42), with tendon cross-sectional area (CSA), lesion cross-sectional area (L-CSA), L-CSA percentage, severity and echogenicity of the lesion, as well as collagen fiber alignment being evaluated. The result revealed reduction (P<0.05) in the L-CSA and in the degree of lesion echogenicity in function of time, but with difference (P<0.05) between groups only for L-CSA, with smaller values in TG. The treatment with PRP promotes greater reduction in the area of the lesion measured by ultrasound.
Abstract in Portuguese:
ABSTRACT.- Maia L., Souza M.V., Alves G.E.S., Júnior J.I.R., Oliveira A.C., Silva Y.F.R.S. & Zandim B.M. 2009. [Platelet-rich plasma in the treatment of induced tendinitis in equines: Ultrasonographic evaluation.] Plasma rico em plaquetas no tratamento de tendinite induzida em eqüinos: avaliação ultra-sonográfica. Pesquisa Veterinária Brasileira 29(3):241-245. Setor de Clínica e Cirurgia de Grandes Animais, Departamento de Veterinária, Universidade Federal de Viçosa, 36570-000 Viçosa, MG, Brazil. E-mail: msouza@ufv.br
The objective of the study was to evaluate the effect of platelet-rich plasma (PRP) in the treatment of induced tendinitis in the superficial digital flexor tendon (SDFT) of horses through ultrasonographic evaluation. Thus, six 8 to15-year-old healthy gelding horses (=12 years) were used. Tendinitis of the SDFT was provoked in both forelimbs via intratendineous administration of 2.5mg of collagenase (2.5mg.mL-1), what was considered as beginning of the experimental phase. Twelve days after induced tendinitis, the horses were submitted to two treatments: (1) in the lesion caused in the right SDFT (treated group, TG), 2.5mL of PRP activated with calcium chloride at 0.0125mol.L-1, at concentrations from 320,000 to 500,000 platelets.µL-1, were administered; (2) in the tendinitis of the left SDFT (control group, CG), 2.5mL of 0.9% saline solution was administered. After 5 days, the animals were submitted to controlled and progressive physical activity during 30 days. Ultrasonographic examinations were carried out before and after tendinitis induction (48 hours after and on experimental days 7, 12, 14, 21 28, 35 and 42), with tendon cross-sectional area (CSA), lesion cross-sectional area (L-CSA), L-CSA percentage, severity and echogenicity of the lesion, as well as collagen fiber alignment being evaluated. The result revealed reduction (P<0.05) in the L-CSA and in the degree of lesion echogenicity in function of time, but with difference (P<0.05) between groups only for L-CSA, with smaller values in TG. The treatment with PRP promotes greater reduction in the area of the lesion measured by ultrasound.
Abstract in English:
ABSTRACT.- Squarzoni R., Morales M., Safatle A.M.V. & Barros P.S.M. 2007. [Ultrasonographic evaluation of the eyes’ posterior segment of diabetic and non-diabetic dogs with cataracts.] Avaliação ultra-sonográfica do segmento posterior de olhos de cães diabéticos e não diabéticos portadores de catarata. Pesquisa Veterinária Brasileira 27(11):455-461. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia (FMVZ), Universidade de São Paulo (USP), Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: renatasq@usp.br
Cataracts jeopardize the light penetration into the eye and may restrain direct exam of eye structures. It is necessary to identify very early any eye disease that could cause the failure of cataract surgery. The ocular ultrasonography or echography is a safe, non invasive, inexpensive and easy procedure that complements ocular examination. Two hundred and twenty five eyes of 123 dogs were evaluated using a 10 Mhz linear transducer ultrasound. The dogs were divided into three groups, as there is Group 1: 36 healthy control dogs; Group 2: 52 non diabetic dogs with cataracts; and Group 3: 35 diabetic dogs with cataracts; all of them were patients of the Veterinary Teaching Hospital, University of Sao Paulo. The ultrasonographic findings were in Group 1: vitreous degeneration in 43%, posterior vitreous detachment in 7.7%, asteroid hyalosis in 4.6% of the eyes; in Group 2: vitreous degeneration in 58.9%, posterior vitreous detachment in 8.4%, asteroid hyalosis in 2.1%, inflammatory or haemorrhagic process in 2.1%, retinal detachment in 4.3% of the eyes; and in Group 3: vitreous degeneration in 50.7%, posterior vitreous detachment in 13.8%, asteroid hyalosis in 12.3%, inflammatory or haemorrhagic process in 3.1%, retinal detachment in 3.1% of the eyes. It could be concluded that (1) diabetic dogs, mainly the ones with diabetes for more than 2 years, have greater chances to develop asteroid hyalosis; (2) there were no significant differences in retinal detachment frequencies for the diabetic and non diabetic dogs; and (3) the ocular ultrasonography is a safe, effective and important exam for the pre-operatory evaluation of dogs with cataracts.
Abstract in Portuguese:
ABSTRACT.- Squarzoni R., Morales M., Safatle A.M.V. & Barros P.S.M. 2007. [Ultrasonographic evaluation of the eyes’ posterior segment of diabetic and non-diabetic dogs with cataracts.] Avaliação ultra-sonográfica do segmento posterior de olhos de cães diabéticos e não diabéticos portadores de catarata. Pesquisa Veterinária Brasileira 27(11):455-461. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia (FMVZ), Universidade de São Paulo (USP), Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: renatasq@usp.br
Cataracts jeopardize the light penetration into the eye and may restrain direct exam of eye structures. It is necessary to identify very early any eye disease that could cause the failure of cataract surgery. The ocular ultrasonography or echography is a safe, non invasive, inexpensive and easy procedure that complements ocular examination. Two hundred and twenty five eyes of 123 dogs were evaluated using a 10 Mhz linear transducer ultrasound. The dogs were divided into three groups, as there is Group 1: 36 healthy control dogs; Group 2: 52 non diabetic dogs with cataracts; and Group 3: 35 diabetic dogs with cataracts; all of them were patients of the Veterinary Teaching Hospital, University of Sao Paulo. The ultrasonographic findings were in Group 1: vitreous degeneration in 43%, posterior vitreous detachment in 7.7%, asteroid hyalosis in 4.6% of the eyes; in Group 2: vitreous degeneration in 58.9%, posterior vitreous detachment in 8.4%, asteroid hyalosis in 2.1%, inflammatory or haemorrhagic process in 2.1%, retinal detachment in 4.3% of the eyes; and in Group 3: vitreous degeneration in 50.7%, posterior vitreous detachment in 13.8%, asteroid hyalosis in 12.3%, inflammatory or haemorrhagic process in 3.1%, retinal detachment in 3.1% of the eyes. It could be concluded that (1) diabetic dogs, mainly the ones with diabetes for more than 2 years, have greater chances to develop asteroid hyalosis; (2) there were no significant differences in retinal detachment frequencies for the diabetic and non diabetic dogs; and (3) the ocular ultrasonography is a safe, effective and important exam for the pre-operatory evaluation of dogs with cataracts.
Abstract in English:
ABSTRACT.- Alves F.R., Costa F.B., Arouche M.M.S., Barros A.C.E., Miglino M.A., Vulcano L.C. & Guerra P.C. 2007. [Ultrasonographic evaluation of the urinary system, liver and uterus of Cebus apella monkey.] Avaliação ultra-sonográfica do sistema urinário, fígado e útero do macaco-prego, Cebus apella. Pesquisa Veterinária Brasileira 27(9):377-382. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: flaviovet@usp.br
The Brown Capuchin, Cebus apella, has a wide distribution in the northern and southern Brazilian Amazon region and in the Cerrado (savanna). These monkeys are usually submitted to predatory chase, increasing the need for preservation of this wild animal species. An ultrasonographic examination of 10 Brown Capuchins was made in order to describe the normal ultrasonographic anatomy of their abdominal cavity. The urinary bladder revealed its wall thickness with an average of 0.2cm, the topographic situation of which allowed close relation with the wall of uterus and descendent colon. Using caudal abdominal scan, images of aorta, caudal vena cava and right iliac vein were obtained. Liver was accessible for examination by sagittal and cross-section ultrasound, allowing visualization of gallbladder and hepatic vessels. Renal scan allowed accuracy to evidence the echogenicity differences between pelvis, renal sinus, as well as the cortical-medullary relationship. The mean length of the kidneys was 6.24±0.31cm, and no significant differences were observed between left and right kidney length (Student’s t-test and ANOVA). The renal volume obtained was 2.37±0.18cm3. Correlation Coefficients of Pearson between right and left renal length and between right and left renal volume were r = 0.74 and 0.51. Mean thickness for cortical and medullar regions was 0.75±0.11 and 0.39±0.06cm, respectively. Correlation Coefficient of corticomedullar relation between right and left renal was r = 0.19. Examination by ultrasound was considered an efficient, non-invasive, fast and repeatable technique which provides useful data for clinicians and surgeons engaged in wild animal medicine.
Abstract in Portuguese:
ABSTRACT.- Alves F.R., Costa F.B., Arouche M.M.S., Barros A.C.E., Miglino M.A., Vulcano L.C. & Guerra P.C. 2007. [Ultrasonographic evaluation of the urinary system, liver and uterus of Cebus apella monkey.] Avaliação ultra-sonográfica do sistema urinário, fígado e útero do macaco-prego, Cebus apella. Pesquisa Veterinária Brasileira 27(9):377-382. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: flaviovet@usp.br
The Brown Capuchin, Cebus apella, has a wide distribution in the northern and southern Brazilian Amazon region and in the Cerrado (savanna). These monkeys are usually submitted to predatory chase, increasing the need for preservation of this wild animal species. An ultrasonographic examination of 10 Brown Capuchins was made in order to describe the normal ultrasonographic anatomy of their abdominal cavity. The urinary bladder revealed its wall thickness with an average of 0.2cm, the topographic situation of which allowed close relation with the wall of uterus and descendent colon. Using caudal abdominal scan, images of aorta, caudal vena cava and right iliac vein were obtained. Liver was accessible for examination by sagittal and cross-section ultrasound, allowing visualization of gallbladder and hepatic vessels. Renal scan allowed accuracy to evidence the echogenicity differences between pelvis, renal sinus, as well as the cortical-medullary relationship. The mean length of the kidneys was 6.24±0.31cm, and no significant differences were observed between left and right kidney length (Student’s t-test and ANOVA). The renal volume obtained was 2.37±0.18cm3. Correlation Coefficients of Pearson between right and left renal length and between right and left renal volume were r = 0.74 and 0.51. Mean thickness for cortical and medullar regions was 0.75±0.11 and 0.39±0.06cm, respectively. Correlation Coefficient of corticomedullar relation between right and left renal was r = 0.19. Examination by ultrasound was considered an efficient, non-invasive, fast and repeatable technique which provides useful data for clinicians and surgeons engaged in wild animal medicine.